In the world of high-precision metal stamping, accuracy is everything. The R-Type Solenoid Valve is a specialized component for pneumatic feeders designed for one critical purpose: to momentarily relax the feeder’s fixed clamp at the perfect instant, enabling advanced error correction and complex stamping operations.

Let’s explore the unique purpose, setup, and troubleshooting of this essential valve.

The Purpose of Precision Relaxation

The R-type valve’s ability to instantly release the material is used in two key scenarios:

1. Error Correction with Pilot Pins: Many stamping dies are equipped with “pilot pins”—tapered pins that enter previously punched holes in the material strip just before the stamping action. Their job is to make micro-adjustments to the material’s position, correcting any tiny feeding errors. For these pins to work, the material must be free to shift slightly. The R-type valve provides this freedom by signaling the fixed clamp to relax at the exact moment the pins engage, ensuring perfect alignment.

2. Preventing Material Tearing in Drawing Operations: In “drawing” or “stretching” operations, the stamping process needs to pull material into the die. If the feeder’s fixed clamp were to hold the material rigidly, this pulling action would cause the material to stretch, thin out, or even tear. The R-type valve prevents this by instantly relaxing the clamp, allowing the material to be drawn smoothly into the die without damage.

Installation and Wiring

The wiring for the R-type valve is a simple circuit. The valve has a 24 VDC coil, normally powered from the press’s 24 V supply (another voltage can be supplied on request), and two wires:

  • One wire connects to Power Source B.
  • The other wire connects to the COMMON terminal on a micro switch.

This circuit is triggered by the micro switch, which is physically activated by the press die.

Setup and Timing Adjustment

Timing is everything for the R-type valve. The goal is to activate the relaxation at the precise moment the die’s pilot pins enter the pilot holes.

  • The Mechanism: This is achieved using a guide rod mounted on the press die. As the press closes, this rod is positioned to make physical contact with and activate the micro switch.
  • The Signal: When the guide rod triggers the switch, an electrical signal is sent to the R-type solenoid valve, which immediately relaxes the fixed clamp.
  • Technical Note: For reliable operation, the guide rod should travel along the micro switch’s actuator for at least a quarter of its total travel distance.

Troubleshooting a Common Fault: Damaged Micro Switch

A faulty micro switch is a common cause of issues with the relaxation system.

  • Symptom: As the press ram descends and the guide rod should be triggering the relaxation, you observe that the feeder either relaxes twice in quick succession or doesn’t perform the relaxation action at all.
  • Diagnostic Test: To confirm the problem, manually press and then quickly release the micro switch with your finger.
  • Diagnosis: If the feeder exhibits the same faulty behavior (a double-action or no-action) when you test the switch manually, it confirms that the micro switch is damaged and needs to be replaced.
Pneumatic Feeder
Pneumatic Feeder