NC servo feeding / Operator reference

NC Servo Feeder
Controls & Operation

Read the touchscreen. Follow the video. Connect each command to what the machine actually does.

HENLI technical guide · Updated September 18, 2026

HENLI NC-300B servo feeder beside its separate touchscreen control cabinet.
The supplied NC-300B equipment photograph shows the feeder and separate control cabinet. Confirm the actual controller version before applying a screen-specific procedure.

An NC servo feeder is easier to understand when you separate four questions: What movement is being requested? Which job values are stored? Which optional functions are configured? What signals is the controller seeing?

This guide explains those questions using HENLI's operating video and the supplied touchscreen photographs. It is an interface reference, not a list of settings to copy. The photographs show one HMI layout; the video and photographs are not confirmed as the same control revision. Match the guidance to your machine before using any command.

Watch / NC feeder controls

Watch the NC feeder setup and operation video

The selected HENLI video, Precision Metal Stamping Automation: NC Servo Feeder Setup & Operation Guide, introduces touchscreen programming, manual feed/retract, multi-stage feeding and release/clamp testing. Watch it alongside your controller documentation to understand how the functions relate.

Watch on YouTube from 00:47 ↗   ·   Watch from the beginning ↗

01 / Read the pictured HMI

OPERATOR: separate manual movement from automatic operation

The photographed OPERATOR page brings together NC JOG+, NC JOG-, Manual-Auto, Auto start and Auto stop. It also shows position, setting, speed and counter fields.

Use these groups to understand the screen:

  • Manual movement: the jog controls identify the two commanded directions. Confirm which direction advances material toward the die on your installation; a plus sign alone does not establish the physical direction.
  • Mode and automatic commands: identify the selected mode separately from a start or stop request. A start button's color does not prove that the line is ready, and an automatic stop command is not a substitute for the emergency-stop system.
  • Displayed information: compare the active job and counter information with the intended production order. A controller position reading does not independently prove that the strip moved the correct distance.

The photograph also includes Reset and Reversion. Confirm their exact effects before using them, especially after an interruption. Do not assume either restores the previous job or provides a safe restart.

NC servo feeder OPERATOR screen showing NC JOG plus and minus, Auto start, Auto stop, Manual-Auto and counter controls.
OPERATOR screen: identify the mode, manual-motion controls and counter state. Displayed numbers are photographic examples, not setup recommendations.

02 / Read the pictured HMI

SETTING: read the field and unit before the number

The SETTING page shows Length, PCS, Speed and Error columns, with five visible step rows. It also includes Step set, Jog speed and several timing fields.

For a job review, identify the intended feed sequence first, then check how this controller represents its lengths, quantities and speed. Confirm what PCS counts and how active steps are selected. Five rows in this photograph describe the screen shown, not the capacity of every NC feeder.

Keep the label ADD time as printed until its definition is confirmed in the matching documentation. Likewise, Master time and Error need their controller-specific definitions; an Error value of zero is not evidence of zero physical feed error.

The displayed numbers are examples, not a recommended recipe. Do not copy a speed or timing value from another machine simply because the screen looks similar.

Example SETTING screen with step rows, Length, PCS, Speed, Error and time fields marked ms or s.
SETTING screen: the photographed version shows five rows. Confirm supported steps, field meanings and units for the actual control; do not copy the displayed values.
Photographed fields What the photograph confirms
ADD time and DEC time Units are shown as ms
Cut time, Master time and Delay time Units are shown as s
Length, Speed, Error and Jog speed Units are not visible

For sequencing concepts, see the multi-step NC feeding guide. Use the documentation for your installed controller to confirm supported steps and behavior.

03 / Read the pictured HMI

FUNCTION: recognize configuration choices

The FUNCTION page contains more than everyday operating commands. The photographed choices include Relaxation signal, Feed for the first time, Cutting mode, Control press and Press mode, alongside Test, Manual cut and Manual press.

These labels help identify what the supplied control program may support. They do not mean every feeder can command a press or cutting device. The screen itself notes that one function depends on a particular PLC configuration.

Treat release-signal selection and press/cut options as integration settings. The displayed Normal open, Continuous and Single selections are not universal recommendations. Before changing them, confirm the intended sequence and approved interface for the connected equipment.

Example FUNCTION screen with relaxation signal, first-feed selection, cutting mode, press mode and manual test controls.
FUNCTION screen: release, cutting and press-control options depend on the fitted machine and connected equipment; a visible button does not establish an installed capability.

04 / Read the pictured HMI

MONITOR: distinguish incoming requests from outputs

The photographed monitor lists a Feed signal and Relaxation signal among the inputs, with outputs labeled Pulse, Direction and Release valve. This makes the page useful for communicating what the controller is receiving and commanding.

For example, when reporting a release problem, distinguish “the release input indication did not change” from “the indication changed, but the rollers did not respond.” Those are different observations, even if the visible symptom seems similar.

This HMI also shows an X2 Input selection: the assignment can relate to automatic start/stop or clamp/release. Do not treat the photographed X/Y labels as a universal wiring schedule, and do not alter signal assignments to make an unexplained symptom disappear.

Example NC servo feeder MONITOR screen with input and output indicators and direction and signal selection controls.
MONITOR screen from the supplied control version. Indicators and selectable input functions must be interpreted against that machine's interface documents.

From screen to machine

Connect the command to the physical response

The NC-300B photographs show the control cabinet, roller entry path and pneumatic hardware. Use these views to connect an on-screen term with the relevant machine area.

During an approved setup check, distinguish the command, the observed movement and the measured result. An illuminated signal does not by itself verify roller release, correct strip travel or synchronization with the press. If the observed response differs from the expected sequence, stop the setup and record the discrepancy before proceeding.

For the wider operating sequence, see our NC feeder operation and maintenance guide.

Close-up of the NC-300B roller head, side guides, adjustment points and pneumatic cylinders.
The roller head and pneumatic hardware provide the physical counterpart to grip and release commands. A screen indication is not proof of the resulting strip movement.

Make the issue clear

Send a support record that identifies the issue

For HENLI support, include:

  • Machine model and serial number, plus a clear HMI-page photograph.
  • Selected mode, active job and any displayed alarm or status.
  • The command or event immediately before the problem.
  • What the controller indicated and what the machine actually did.
  • Whether the issue followed a job change, restart or other intervention.

Photograph exterior identification and safely accessible information. Do not open an energized cabinet merely to collect a component picture.

Open NC servo feeder control cabinet showing the touchscreen area above internal control and drive components.
Cabinet layout reference. An open-door photograph is not an approved operating condition and does not authorize live electrical inspection.
Internal view of an NC servo feeder cabinet showing the PLC, relays, servo drive and terminal area.
Component view for identification, not a wiring guide. Cabinet access requires qualified personnel and the specified electrical isolation and discharge procedure.

Quick answers

NC feeder control questions

Can I copy the photographed settings?

No. They are display examples. Confirm the applicable units, material, tooling, feed sequence and approved operating limits for your machine.

Does Auto stop isolate the equipment?

No. Treat it as an operating command, not energy isolation. Follow the machine's emergency-stop and isolation procedures as applicable.

Why does my screen look different?

HMI layouts and available functions vary with the controller and supplied configuration. Send your screen and machine identification so HENLI can review the relevant version.

Your machine / Your control version

Need help with an NC feeder screen?

Send the machine model, a clear screen photo and the observed symptom. HENLI can review the relevant configuration with you.

Reference material: HENLI’s linked operation video and the supplied NC-300B / HMI photographs. The video and photographs are separate references, not proof of one identical control revision. All photographed settings are examples.

Use the approved documentation and safety procedures for the actual feeder, press and connected equipment. Cabinet photographs are for identification, not electrical instructions; isolation and stored-energy discharge must follow the equipment manufacturer’s procedure.