Hydraulics · Maintenance

Hydraulic System Maintenance for Decoiler Straightener Feeders: Oil Temperature, Cooling and Checks

On a decoiler straightener feeder, the hydraulics expand the mandrel and can also work the press arm and the coil car. This guide shows how hot the oil may run, how to check that the tank and cooler can carry the heat, and what to inspect on each part.

Maintenance guide · 8 min read · 1 calculator

Heavy-duty decoiler line in a workshop with its hydraulic power unit to the right of the decoiler
A heavy-duty decoiler line with its hydraulic power unit, to the right of the decoiler.
60 °CHighest oil temperature to run at. A temperature switch can start the cooler there.
80 °CAbove this, seals and other parts wear fast and can fail.
4.1 kWHeat a 300 L tank sheds by itself in a 25 °C workshop, up to 60 °C.
2,100 LTank you would need to shed 15 kW without a cooler.

On a decoiler line, two things keep the hydraulics reliable: an oil temperature the seals can live with, and regular care of a few parts.

This guide covers what the hydraulic system drives, how hot the oil may run, how to check the heat balance of the tank and the cooler, what to inspect part by part, and what to look at first when the oil runs hot.

The short answer

Keep the hydraulic oil at or below about 60 °C; above 80 °C, seals and other parts wear fast. The heat to remove is, at worst, the full motor power, when the pump runs but nothing moves. A steel tank sheds k × A × (oil − ambient temperature), about 4 kW for a 300 L tank in a workshop, so most systems need an air or water cooler for the rest. Check that balance for your climate, then keep the oil clean, the level right and the cooler running.

01What it drives

What the hydraulic system drives on a decoiler line

The hydraulic power unit drives the motions that need force: expanding the mandrel inside the coil and, depending on the line, pressing the arm onto the coil and lifting and moving the coil car.

An electric motor drives a pump that pressurizes oil from the tank. Valves set its pressure, direction and flow; cylinders and hydraulic motors turn it into motion; filters, an accumulator and a cooler keep it clean, steady and cool.

The tank has two jobs: it stores the oil and it sheds heat. It must hold more oil than all the cylinders can take in at once, or the pump ends up drawing air. For how the cylinders and the expansion are sized, see the decoiler design calculations.

Labelled hydraulic decoiler: main motor, press arm, hydraulic expansion device, spindle head support and hydraulic feeding trolley
The main parts of a hydraulic decoiler: the hydraulic expansion device grips the coil, and a hydraulic trolley brings it to the mandrel.

02Oil temperature

How hot the oil may run

Run the oil at or below about 60 °C. Above 80 °C, seals and other parts wear fast and can fail.

A temperature switch can start the oil cooler when the oil reaches 60 °C. Check the temperature near the pump suction while the line is in production.

How far the oil may warm up depends on the climate. Where the workshop sits at 10–20 °C, the oil can rise 40 °C or more before it reaches the limit. Where it is 40–50 °C, as in hot regions, only about 10 °C of rise is left, and the cooler has to do much more.

Allowed rise by climate

Cool workshop, 10–20 °C: about 40 °C or more of rise.

Typical workshop, 25 °C: 35 °C of rise to 60 °C.

Hot region, 40–50 °C: about 10 °C of rise.

03Heat balance

Check the heat balance: tank, cooler and climate

Work out the heat first. At worst it is the full motor power: when the pump runs but nothing moves, all of its power turns into heat. While the cylinders work, the work they do comes off that figure.

tank heat loss (W) = k × A × (oil temperature − ambient)tank surface A ≈ 0.065 × V^(2/3) (m², V in litres)k for a steel tank in still air: 28–57 W/m²·K; about 40 in a normal workshop, lower in a cramped corner, higher with good ventilation or a fan.

A 300 L tank in a 25 °C workshop, allowed to reach 60 °C, sheds about 4.1 kW. To shed 15 kW by itself, the tank would need about 2,100 litres, so the rest goes to a cooler.

Air coolers are rated by their air flow, water coolers by their water flow and the temperature rise between inlet and outlet. In the example, the tank's 4.1 kW plus an 8 kW water cooler still falls short of 15 kW, so a larger cooler is needed. When the cooling falls short, the oil keeps warming until the tank sheds the difference, at a balance temperature above the limit.

Storage comes first

Before the heat balance, check the volume: the tank must hold more oil than all the cylinders can take in at once. Otherwise the pump draws air.

Try itOil heat balanceEnter the heat to remove, the tank and the cooler. See what the tank sheds, whether the cooling is enough, and where the oil temperature would settle.
Heat to remove against tank and cooler capacityA bar for the heat to remove, a bar for what the tank and the cooler can shed, and a temperature scale showing where the oil would settle, with the 60 degree limit and the 80 degree seal-risk mark.Heat to removeCooling15.0 kWTank 4.1 kW + cooler 8.0 kWshort 2.9 kWOil temperature20°C40°C60°C80°C100°Climitseals at riskabout 85°C
TankCoolerShortfall
Tank sheds4.1 kW
Tank + cooler12.1 kW
CoolingNot enoughShort by 2.9 kW: choose a cooler of at least 10.9 kW. The tank alone would need about 2,100 L.
Oil would settle atabout 85 °CAbove 80 °C: seals and other parts are at risk.
Tank area A ≈ 0.065 × V^(2/3) (m², V in litres). Tank heat = k × A × (oil limit − ambient). The cooler is taken at its rated capacity. Settling temperature = ambient + (heat − cooler) ÷ (k × A). Worst-case heat = motor power, when the pump runs but nothing moves.

04Maintenance checks

What to check, part by part

1

Oil tankKeep the level between the marks and never remove the strainer at the filler. Drain the bottom now and then, test the oil every 2–3 months, clean the tank and filters before refilling, and keep the breather clean.

2

Pump and suctionClean the suction filter, watch the suction vacuum and stop air getting in at the joints. Grease the pump coupling as the maker specifies, typically every 1–6 months, and check the discharge pressure.

3

ValvesCheck that the pressure setting adjusts smoothly, that the cylinders move without shocks, with no loose screws, and that the flow controls give the speed you need.

4

CylindersKeep each cylinder in line with what it moves, the hoses free to flex and dirt off the rod. Check for internal leakage at the return line.

5

Filters, accumulator and coolerClean or replace the filters and check the accumulator's nitrogen pressure. Check water coolers for leaks, clean the fins of air coolers, and tighten pipe supports and fittings.

Hydraulic decoiler with an orange mandrel for a metal stamping press line
A hydraulic decoiler for a stamping press line, with hydraulic mandrel expansion.

05When oil runs hot

When the oil runs hot

Look for the simple causes first.

1

Is the cooler running?A water cooler that is switched off, or a fan that does not turn, can push the oil above 80 °C.

2

Is the cooler clean?Clean the fins of an air cooler; check the water flow and temperature of a water cooler.

3

Does the balance fit the real conditions?Recheck the heat balance with the real workshop temperature and duty, not a catalog ambient.

4

Is oil running over the relief valve?When the pump pushes oil over the relief valve with nothing moving, its power turns straight into heat.

5

Is the level right?Top up to the mark and look at the oil: replace it if it is dark or contaminated.

Above 80 °C, stop and find the cause

Seals and other parts wear fast at that temperature. Find out why the oil runs hot before the line runs again; do not just wait for it to cool.

HENLI decoilers

Decoilers with hydraulic expansion and loading

Each product page has the full specifications, photos and a quotation checklist.

See all HENLI decoilers ›

?FAQ

Hydraulic oil and cooling questions

What is the maximum hydraulic oil temperature?

Keep it at or below about 60 °C. Above 80 °C, seals and other parts wear fast and can fail.

How do I know if my tank and cooler are big enough?

Compare the heat to remove with what the tank sheds, k × A × (oil limit − ambient), plus the cooler's rated capacity. If the total is short, the oil keeps warming and settles above the limit.

How much heat does a hydraulic tank shed?

About 4 kW for a 300 L steel tank in a 25 °C workshop allowed to reach 60 °C. The coefficient k is 28–57 W/m²·K, about 40 in a normal workshop.

Why does the oil get hotter when the machine is not moving?

When the pump runs but nothing moves, all of its power turns into heat. That is the worst case the tank and cooler have to carry.

How often should the hydraulic oil be checked?

Test it every 2–3 months and replace it if it is contaminated. Clean the tank and the filters before refilling.

Air cooler or water cooler?

Size it from the heat balance. If an air cooler cannot carry the shortfall, use a water cooler, rated by its water flow and the temperature rise between inlet and outlet.

Hydraulic check

Need a Hydraulic Check for Your Decoiler?