Upgrading your pneumatic air feeder with an E-Type Solenoid Valve allows for precise electronic control over its timing, a significant improvement over purely mechanical systems. This guide will walk you through the installation process step-by-step.

Safety First: Before you begin, ensure the machine is completely powered off and that the compressed air supply has been disconnected and the system fully depressurized.

Step 1: Remove the Existing Floating Rod

The first task is to remove the old mechanical actuator to make room for the new valve system.

  1. Pull the floating rod on the air feeder to its highest position.
  2. Using a pair of snap ring pliers, carefully remove the snap ring that holds the assembly in the main body of the feeder.
  3. Firmly pull the floating rod out of its housing.
    • Helpful Tip: If the rod is stuck, you can briefly open the air valve switch. The air pressure will help push the rod out, making it easy to remove.

Step 2: Ensure an Airtight Seal

To prevent air leaks, which can cause pressure loss and poor performance, every threaded connection must be properly sealed.

  • On the threads of every pipe joint and elbow fitting, wrap thread seal tape (Teflon tape) two to three times.
  • Crucial Detail: Always wrap the tape counter-clockwise, against the direction of the threads. This ensures the tape tightens into the threads as you screw the fitting in, rather than unraveling.

Step 3: The Solenoid Valve Installation Sequence

Follow this precise order to correctly assemble the new components.

  1. Install the Control Valve Plug:
    • First, screw the I-type elbow fitting into the control valve plug.
    • Place the small O-ring onto the control valve plug and the large O-ring into the groove inside the main body’s hole.
    • Carefully push the entire control valve plug assembly into the main body and secure it by reinstalling the snap ring.
  2. Connect the L-Type Elbow:
    • Take the L-type elbow fitting and screw it into the port marked ‘B’ on the E-type solenoid valve. This elbow can be rotated to face any direction you need for routing the air lines.
  3. Install the T-Fitting:
    • Remove the existing elbow from the side of the feeder’s main body and replace it with the new T-fitting.
    • Attach threaded connectors to the two remaining ports of the T-fitting.
    • Connect one side of the T-fitting to the hole on the side of the feeder’s main body.
    • Connect the other side of the T-fitting to the port marked ‘C’ on the E-type solenoid valve.
  4. Connect the Nylon Air Lines:
    • Finally, connect the nylon tubing to complete the pneumatic circuit. Run the tubing between the I-type elbow and the L-type elbow, and then to the T-fitting. Ensure all connections are pushed in firmly and locked in place.

Step 4: Understanding the Manual Override Button

On the top of the E-type solenoid valve, you will notice a red mark or button. This is a very useful feature for testing.

  • Function: This is a manual override. Pressing the red button simulates the valve receiving an electrical signal, causing it to activate. This allows you to test the pneumatic function of the feeder without needing to connect power or run the press, making it excellent for troubleshooting and setup.
Air Feeder