How Do Safety Light Curtains Work? Beams, Types and Safety Distance
A safety light curtain stops a press when a hand enters the die area. Here is how the beams detect it, what resolution and Type 2 or Type 4 mean, how far from the die it must be mounted, and where it goes on a coil-fed punch press.
A punch press closes with tens or hundreds of tons. A safety light curtain is one way to keep hands out of that motion: an invisible field across the die opening that stops the stroke the moment it is broken.
This guide explains how a light curtain works, what resolution and Type 2 or Type 4 mean, how the safety distance is calculated, where the curtain goes on a coil-fed press, how it connects to the press stop circuit, and what to test every day. A calculator gives a first estimate of the safety distance.
A safety light curtain is a transmitter and a receiver facing each other. The transmitter sends infrared beams one after another; the receiver checks each one. When an object blocks any beam, the receiver switches its outputs off and the press safety circuit stops the slide. Resolution, the smallest object detected, comes from the beam pitch: about 14 mm for fingers, 20–40 mm for hands. Type 4 devices under IEC 61496 are meant for high-risk machines such as presses. The curtain must sit far enough from the die that a hand cannot reach it before the press stops: ISO 13855 gives S = 2000 × T + 8 × (d − 14) for resolutions up to 40 mm.
01How it works
How a safety light curtain detects a hand
A light curtain is two bars facing each other across the opening: a transmitter with a row of infrared emitters, and a receiver with a matching row of sensors.
ScanThe transmitter fires its beams one at a time, top to bottom, and the receiver looks for each beam in step. The scan repeats many times a second.
DetectIf any beam does not arrive, something is in the field. Stray light is rejected because the receiver only accepts pulses that arrive in step with the transmitter.
SwitchThe receiver switches its outputs off. Safety-rated curtains use two outputs that are checked against each other.
Stop and resetThe press safety circuit stops the slide. When the field is clear again, the press restarts only after a reset, where the restart interlock is used.
The curtain itself is a sensing device. Stopping the press safely depends on the safety controller, the press control and the press's own stopping performance.
Transmitter and receiver pairs with 20 mm or 40 mm beam pitch.
Protection heights from 60 to 600 mm, 4 to 16 beams.
Sensing range 0.3–3 m, response time below 15 ms.
10–30 V DC supply, IP66 housing, built-in self-check circuitry, 3-year warranty.
02Resolution
Resolution and beam pitch: what the curtain can detect
Resolution, also called detection capability, is the smallest object the curtain is guaranteed to detect anywhere in its field.
It comes from the beam pitch and the beam size: an object smaller than the gap between beams can slip through. The finer the resolution, the smaller the body part detected, and the closer to the die the curtain may be mounted.
| Resolution | Detects | Typical use |
|---|---|---|
| About 14 mm | A finger | Closest mounting to the die |
| About 20–40 mm | A hand | Most press front openings |
| Coarser, multi-beam | An arm or the body | Perimeter and access openings, mounted much farther away |
The QPZ series comes in 20 mm and 40 mm beam pitch. Which detection capability a given model achieves, and the safety distance it needs, is confirmed on the quotation and the datasheet.
03Type 2 vs Type 4
Type 2 vs Type 4: how much the curtain is trusted
IEC 61496 sorts safety light curtains into types by how well they resist faults and stray light.
Type 4Tighter limits on the beam's opening angle, so reflections from nearby shiny surfaces cannot bridge a blocked beam, and fault detection good enough that a single fault cannot leave the machine running. Meant for high-risk machines.
Type 2Looser limits and periodic testing instead of continuous fault detection. Meant for lower-risk machines.
The machine decidesMechanical power presses are normally treated as high risk, so the press maker and the risk assessment usually call for a Type 4 device and a matching safety level for the whole circuit.
The type is stated on the device's datasheet and certificate. Check it against the risk assessment for your press before ordering.
The safety distance: it still has to be calculated.
Access around, over or under the field: it still has to be closed with fixed guards.
The press stop circuit: it still has to be designed and validated.
04Safety distance
Safety distance: how far from the die
The curtain must sit far enough from the die that a hand passing through the field cannot reach the hazard before the slide has stopped.
Total stopping time TThe press's measured stopping time, plus the curtain's response time and the safety controller or relay's response time.
Approach speed KISO 13855 uses 2,000 mm/s for hand approach at short distances and 1,600 mm/s above 500 mm; ANSI B11.19 and OSHA in the US use 63 in/s, the same 1,600 mm/s.
Intrusion allowance CHow far a hand can reach through the field before it is detected: 8 × (d − 14) mm for resolutions up to 40 mm, and 850 mm for coarser devices.
ResultS = K × T + C, with a minimum of 100 mm. Blanking beams makes the resolution coarser and the distance longer.
Press stopping time grows as the brake wears: measure it, and recheck it at intervals.
Use the longest stopping time at the slowest-braking point of the stroke.
If the distance does not fit, a finer resolution or a faster-stopping press shortens it; a fixed guard may suit better.
05On a coil-fed press
Where the curtain goes on a coil-fed punch press
A light curtain protects one opening. On a coil-fed press every other way into the die has to be closed too.
Front openingThe curtain covers the operator side, high enough that no one can reach over it and low enough that no one can reach under it.
Sides and backFixed guards or guard doors close the openings that the curtain does not see. A curtain that can be walked around protects nothing.
Strip entry and exitThe coil strip enters from the feeder side. The feeder area, the strip entry and the scrap exit are guarded so a hand cannot follow the strip into the die; see the pass line guide for the feeder side.
Feeder and press togetherThe feeder runs only when the press control allows it; see feeder and press synchronization.
Not for every pressA light curtain can stop a press only if the press can stop partway through the stroke. It is not a suitable safeguard on a press with a full-revolution clutch.
06Wiring and stop circuit
Wiring: from the curtain to the press stop circuit
The curtain only reports; the safety controller and the press control do the stopping.
Curtain outputsThe receiver's outputs go to a safety controller or safety relay. The QPZ series offers relay-output (-J) and transistor-output versions; the wire colors depend on the version, so wire from the diagram supplied with the unit.
ControllerThe controller monitors the outputs, handles reset and restart, and switches the press stop circuit. QPZ is available with an external controller.
Press stop circuitThe press maker, or a qualified integrator, connects the controller to the clutch and brake control so that a broken field stops the slide.
ValidationThe complete circuit is tested and recorded before production: the curtain, the controller, the press stop and the measured stopping time.
HENLI supplies the QPZ light curtains and the coil feeding equipment; for the press, HENLI works with partner press makers such as GOANWIN and can introduce one. The press types are compared in the gap frame vs straight-side guide and the servo, mechanical and hydraulic press guide.
07Daily checks
What to check every day
A light curtain is only as good as its last test. Check it at the start of every shift and after any die change.
- Pass a test rod of the stated resolution slowly through the field at the top, middle and bottom: the press must not be able to stroke.
- Check that no one can reach over, under or around the field, including from the feeder side.
- Check that the brackets are tight and the transmitter and receiver are still aligned.
- Clean the front windows; oil mist and dust weaken the beams.
- Check that the indicator lamps show the normal state and that reset works as intended.
Line safety in general: the stamping production line safety guide.
The operator's daily routine: the press operator guide.
HENLI equipment
Press safety and coil feeding
Each page has the specifications, photos and a quotation checklist.
?FAQ
Safety light curtain questions
How does a safety light curtain work?
A transmitter sends a row of infrared beams to a receiver, one beam at a time in a fast scan. When an object blocks one or more beams, the receiver switches its outputs off, and the machine's safety circuit stops the hazardous motion. The press cannot restart until the field is clear and, where required, a reset is pressed.
What is light curtain resolution?
Resolution, or detection capability, is the smallest object the curtain is guaranteed to detect anywhere in its field. Around 14 mm detects a finger, around 20–40 mm detects a hand, and coarser multi-beam devices detect only an arm or the body. Resolution depends on the beam pitch and the beam diameter.
What is the difference between a Type 2 and a Type 4 light curtain?
Both are defined in IEC 61496. A Type 4 device has stricter limits on beam spread and fault detection and is meant for high-risk machines; a Type 2 device is for lower risk. Mechanical power presses are normally treated as high risk, so the press maker and the risk assessment usually call for Type 4. Check the type on the device's datasheet and certificate.
How far from the die must a light curtain be?
Far enough that a hand passing through the field cannot reach the die before the press has stopped. ISO 13855 gives S = 2000 × T + 8 × (d − 14) for resolutions up to 40 mm, where T is the total stopping time in seconds and d the resolution in millimeters; the US uses ANSI B11.19 and OSHA with a hand speed of 63 in/s. The calculator in this guide gives a first estimate.
Can a light curtain be used on any punch press?
No. A light curtain stops a press only if the press can stop partway through the stroke. Presses with a full-revolution clutch cannot, so presence-sensing devices are not suitable as the safeguard on them.
What are muting and blanking?
Muting switches the curtain off for a defined, safe part of the cycle. Blanking ignores selected beams, for example where coil strip or a fixture passes permanently through the field. Blanking makes the effective resolution coarser, so the safety distance must be recalculated.
How is a light curtain wired to a press?
The curtain's outputs go to a safety controller or safety relay, which is wired into the press stop circuit by the press maker or a qualified integrator. The HENLI QPZ series offers relay and transistor output versions and an external controller.
What should be checked every day?
That the curtain stops the press when a test object of the stated resolution is passed through the field at several heights, that no one can reach around, over or under it, that the mounting is tight and aligned, and that the lenses are clean.