Related AF model data: This article explains feed length setup. For maximum feeding length by AF model, use the AF pneumatic air feeder model page before confirming the feeder size. Open AF pneumatic air feeder models.

The primary function of a pneumatic Air Feeder is to push a precise, repeatable length of material into a stamping press. Mastering the art of setting this feed length is the key to producing accurate parts. The process involves a combination of coarse mechanical adjustments and fine-tuning.

Here is a detailed guide to get it right every time.

Phase 1: Preparing the Feeder for Adjustment

Before you can measure or adjust anything, you must put the feeder into a safe, manual mode.

  1. Shut Off the Air Supply: The first and most important step is to close the air valve. You can do this by pushing the valve switch in the direction of the quick-connect fitting. You will hear a hiss as the feeder releases its internal air pressure.
  2. Loosen the Speed Control: To make the internal components easy to move by hand, turn the speed adjustment screw counter-clockwise one or two full rotations. This reduces the pneumatic resistance, allowing the main slider to move freely.
  3. Open the Air Supply (When Ready): Once your adjustments are complete, you will re-engage the air by pushing the air valve switch in the opposite direction of the quick connector. You will know it’s on when the floating rod automatically rises.

Phase 2: The Two-Part Adjustment Process

Setting the feed length is a two-step process: a coarse adjustment using spacer rings and a fine adjustment using a micro-adjustment screw.

Step A: Coarse Adjustment with Spacer Rings

The “spacer rings” are physical blocks that define the maximum travel distance of the feeder’s slider.

  • To Begin: First, loosen the locking screw located under the feeder’s main stop block. Then, completely remove the fine-tuning screw.
  • The Principle: The feed length is determined by the travel distance of the internal slider. By adding or removing spacer rings, you physically change this distance. The more spacer rings you remove, the longer the potential feed length will be.

Step B: Fine-Tuning with the Micro-Adjustment Screw

Once your coarse adjustment is close to the target length, you will use the micro-adjustment screw to dial it in perfectly.

  • Clockwise Rotation: Turning the screw clockwise shortens the feed length.
  • Counter-Clockwise Rotation: Turning the screw counter-clockwise lengthens the feed length.
  • Precision Tip: One full 360° rotation of this screw adjusts the feed length by exactly 1mm, allowing for very precise control.

Phase 3: The Art of Accurate Measurement

With the feeder prepared and the air off, you can now accurately measure the feed distance you have set.

  1. Use the Right Tool: A digital caliper or a set of gauge blocks is recommended for this task.
  2. Identify the Measurement Points: The feed length is the distance the slider travels between the stationary washer at one end and the stack of spacer rings at the other. You will be measuring the length of this gap.
  3. The Technique for Accuracy: To get a truly precise reading, you must follow this three-step cycle:
    • Push the slider firmly against the washer at the back.
    • Push the slider firmly against the spacer rings at the front.
    • Measure the travel distance.
    • Repeat this entire process three times. Taking multiple measurements and ensuring they are consistent eliminates any slack or error, guaranteeing your final setting is exact.